1. There’s no reason to compromise.

    We believe in doing more with less. Nowhere is that more apparent than with Gardner Denver’s line of stimulation and fracturing pumps, which maximize flow rates and pressure capabilities with a minimal footprint.

    Drilling Extra

    Gardner Denver Stimulation and Fracturing Pumps

GD-3000 Pump Model

  1. Stimulation and Frac Pumps - GD 3000 BHP

Reciprocating, Triplex Stimulation and Fracturing Pump - 3,000 BHP

Field-proven as the most powerful well-stimulation pump on the market, the durable GD-3000 does what no other pump can do. It combines high-pressure and high-flow rate capabilities into a single, lightweight unit. A variety of fluid-end options are also available to cover all your pressure and flow requirements

  • Maximum Pressure: 22,000 psi
  • Maximum Flow: 1,375 gpm
  • Weight: 18,550 lbs.

Design Advantages

  • Modular frame for lightweight, yet durable construction.
  • Planetary gear reduction with offset for maximum power to weight ratio.
  • Premium fluid end material and standard autofrettage for extended service life.
  • High strength forged crankshaft.
  • Standard gun sight or new falcon style suction valve retainers for ease of service.

Documents

  • Performance Chart

    Pump Model Horsepower
    [BHP]
    Stroke
    [IN]
    Piston/Plunger
    Diameter [IN]
    (Min) (Max)
    Piston Load
    [LBS]
    Rate [GPM]
    (Min) (Max)
    Pressure Ranges [PSI]
    (Min) (Max)
    GD-3000 3,000 11 4.5 / 7 350,000 114 / 1,375 3,350 / 22,000
    Pump Model Horsepower
    [kW]
    Stroke
    [MM]
    Piston/Plunger
    Diameter [MM]
    (Min) (Max)
    Piston Load
    [N]
    Rate [m3/hr]
    (Min) (Max)
    Pressure Ranges [BAR]
    (Min) (Max)
    GD-3000 2,237.1 279.4 114.3 / 177.8 1,556,877.6 25.9 / 312.3 231 / 1,516.8
  • Performance Comparison Chart

    Pump Model Horsepower
    [BHP]
    Stroke
    [IN]
    Piston/Plunger
    Diameter [IN]
    (Min) (Max)
    Piston Load
    [LBS]
    Rate [GPM]
    (Min) (Max)
    Pressure Ranges [PSI]
    (Min) (Max)
    GD-3000 3,000 11 4.5 / 7 350,000 114 / 1,375 3,350 / 22,000
    GD-2500Q 2,500 8 3.8 / 6.8 196,350 191 / 2,044 1,900 / 17,800
    C-2500 2,500 8 3.8 / 7.5 225,000 191 / 2,523 1,550 / 20,000
    GD-2250T 2,225 8 3.8 / 7 237,500 115 / 1,319 2,293 / 21,500
    Thunder Triplex 2,550 11 4 / 7.3 275,000 0 / 1,769 0 / 20,000
    Pump Model Horsepower
    [kW]
    Stroke
    [MM]
    Piston/Plunger
    Diameter [MM]
    (Min) (Max)
    Piston Load
    [N]
    Rate [m3/hr]
    (Min) (Max)
    Pressure Ranges [BAR]
    (Min) (Max)
    GD-3000 2,237.1 279.4 114.3 / 177.8 1,556,877.6 25.9 / 312.3 231 / 1,516.8
    GD-2500Q 1,864.2 203.2 95.3 / 171.5 873,408.3 43.4 / 464.2 131 / 1,227.3
    C-2500 1,864.2 203.2 95.3 / 190.5 1,000,849.9 43.4 / 573 106.9 / 1,379
    GD-2250T 1,659.2 203.2 95.3 / 177.8 1,056,452.6 26.1 / 299.6 158.1 / 1,482.4
    Thunder Triplex 1,901.5 279.4 101.6 / 184.2 1,223,260.9 0 / 401.8 0 / 1,379